Unit of Measure
Items
KPN Series Bar Graph Temperature Controller

KPN Series Bar Graph Temperature Controller

T3/T4 Series Thumbwheel Switch Temperature Controller

T3/T4 Series Thumbwheel Switch Temperature Controller

TA Series Analog Non-Indication Type Proportional-Integral-Derivative (PID) Temperature Controller

TA Series Analog Non-Indication Type Proportional-Integral-Derivative (PID) Temperature Controller

TC Series Single Display Proportional-Integral-Derivative (PID) Temperature Controller

TC Series Single Display Proportional-Integral-Derivative (PID) Temperature Controller

TC3YF Series Refrigeration Temperature Controller

TC3YF Series Refrigeration Temperature Controller
Description N/A
Brands N/A Autonics
Model N/A KPN N/A T3/T4-TC N/A TA N/A TC N/A TC3YF
Type N/A Temperature Controller
Direct Current (DC) Power Supply Voltage N/A N/A 100 to 240 V N/A 100 to 240 V N/A N/A
Permissible Voltage Range N/A 90 to 110 % of rated voltage N/A 90 to 110 % of rated voltage N/A 90 to 110 % of rated voltage N/A 90 to 110 % of rated voltage N/A 90 to 110% of rated voltage
Display Type N/A 7 Segment (red, green), control output bar graph (red, green), Light Emitting Diode (LED) type N/A 7 Segment (red), Light Emitting Diode (LED) Type N/A PV deviation, Error display (red, green), Light Emitting Diode (LED) Type N/A 7 Segment (red, green, yellow), Light Emitting Diode (LED) Type N/A 7 Segment (red), Light Emitting Diode (LED) Type
Dielectric Strength N/A Between the charging part and the case: 3,000 VAC ~ 50/60 Hz for 1 minute N/A Between the charging part and the case: 2,000 VAC 50/60 Hz for 1 minute N/A Between the charging part and the case: 2,000 VAC 50/60 Hz for 1 minute N/A N/A Between the charging part and the case: 2,000 VAC 60 Hz for 1 minute
Vibration N/A 0.75 mm amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction for 2 hours N/A 0.75 mm amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours N/A 0.75 mm amplitude at frequency of 5 to 55 Hz in each X, Y, Z direction for 2 hours N/A 0.75 mm amplitude at frequency 5 to 55Hz in each X, Y, Z direction for 2 hours N/A 0.75 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours
Memory Retention N/A ≈ 10 years (Non-volatile Semiconductor Memory type) N/A N/A N/A N/A
Ambient Temperature N/A -10 to 50 ºC, Storage: -20 to 60 ºC (No Freezing or Condensation)
Ambient Humidity N/A 35 to 85% RH, Storage: 35 to 85% RH (No freezing or Condensation) N/A 35 to 85%RH, storage: 35 to 85%RH (No Freezing or Condensation) N/A 35 to 85%RH, storage: 35 to 85%RH (No Freezing or Condensation) N/A 35 to 85%RH, storage: 35 to 85%RH (No Freezing or Condensation) N/A 35 to 85%RH, storage: 35 to 85%RH (No Freezing or Condensation)
Ambient Relative Humidity N/A
Power Supply Frequency N/A N/A 50 Hz60 Hz N/A 50 Hz60 Hz N/A N/A
Power Consumption N/A N/A ≤ 5 V·A N/A ≤ 4 V·A N/A N/A
Sampling Period N/A N/A 100 ms N/A 100 ms N/A 100 ms N/A 500 ms
Input Specification N/A N/A Refer to 'Ordering Information: Input type and using range'. N/A N/A Refer to 'Input Type and Using Range'. N/A Refer to 'Input Type and Using Range'.
Control Type N/A N/A ON/OFF, Proportional control N/A N/A N/A ON/OFF Control
Hysteresis N/A N/A F.S. 0.2 to 3% (T3S: F.S. 0.5%) (volume switch) N/A N/A 1 to 100 ºC0.1 to 50.0 ºF N/A 0.5 to 5.0 ºC2 to 50 ºF
Proportional Cycle N/A N/A 20 sec N/A N/A N/A
Integral Time (I) N/A N/A N/A N/A 0 to 9,999 sec N/A
Insulation Resistance N/A
Power Consumption for Maximum Load N/A
Noise Immunity N/A ± 2 kV square shaped noise (pulse width 1 µs) by noise simulator R-phase, S-phase N/A N/A N/A N/A
Features N/A
  • High speed sampling of 50ms and ±0.3% display accuracy
  • Enable to check control output operation amount by adopting bar graph
  • Simultaneous heating/cooling control and automatic/manual control for high performance control
  • Selection function of current output or SSR drive output
  • Parameter setting available via PC (USB and RS485 communication)
    • Free device comprehensive management program (DAQMaster)
  • Communication converter sold separately: SCM-US (USB/Serial converter), SCM-38I (RS232C/RS485 converter) SCM-US48I (USB/RS485 converter)
  • Multi-SV (Max. 4) function (select via digital input terminal)
  • Heater break alarm
  • CT sold separately: CSTC-E80LN, CSTC-E200LN, CSTS-E80PP
  • Small size (rear length: 60 mm)
  • Multi input/multi range
N/A
  • Various control output options : relay, SSR drive, current
  • 2 independent set points and control outputs for heating and cooling control (T4LP)
  • Various sizes (W48 x H48, W48 x H96, W72 x H72, W96 x H96 mm)
N/A
  • Auto-tuning PID temperature control
  • PID and ON/OFF control : toggle via external switch
  • Deviation indicators (green, red LED)
  • Control output indicator (red LED)
  • Stop control output function using analog dial
  • Sensor disconnect display function
  • Built-in microprocessor
N/A
  • Single digital display (switch between PV and SV)
  • 100ms high-speed sampling rate and ±0.5% display accuracy
  • Switch between relay output and SSR drive output (patent)
  • SSR drive output (SSRP function) control options : ON/OFF control, cycle control, phase control
  • Compact design with large display panels for easier reading
  • Connector plug types offer easier wiring and maintenance (TCN4S-P)
    • Korea Patent Registration 10-1002582, U.S.A. Patent Registration 8645000, Japan Patent Registration 3184816, China Patent Registration ZL200980111733.X, Vietnam Patent Registration 1-0012131, India Patent Registration 291573, Indonesia Patent Registration IDP003216
N/A
  • ON/OFF control
  • Standard input type : thermistor (NTC)
    • RTD(Pt100Ω) input models available upon request.
  • Temperature range
    • Thermistor (NTC) : -40.0 to 99.9 ºC (-40 to 212 ºF)
    • RTD (Pt100 Ω) : -99.9 to 99.9 ºC (-148 to 212 ºF)
  • Various functions available for optimal cooling control
    • Auto/manual defrost selection, compressor start-up delay, restart delay, minimum ON time, end-defrost delay, evaporator fan operation delay
  • Input correction function
  • Operation cycle programming available to protect contents in case of error