Unit of Measure
Items
BF4 Series Button Adjustment Fiber Optic Amplifier

BF4 Series Button Adjustment Fiber Optic Amplifier

BF5 Series Single/Dual Display Fiber Optic Amplifier

BF5 Series Single/Dual Display Fiber Optic Amplifier

BFX Series Dual Display Fiber Optic Amplifier

BFX Series Dual Display Fiber Optic Amplifier
Description N/A
Brands N/A Autonics
Model N/A BF4 N/A BF5 N/A BFX
Type N/A Amplifier
Maximum High Response Time N/A 0.5 ms N/A N/A
Response Time N/A Built-in 2 differential frequencies (frequency 1: ≤ 0.5 ms, frequency 2: ≤ 0.7 ms) N/A N/A
Sensitivity Setting N/A Button/Remote sensitivity setting N/A N/A
Operation Mode N/A Light ON/Dark ON Selectable N/A N/A
Indicator N/A Operation Indicator (Red), Stability Indicator (Green) N/A N/A
Current Consumption N/A ≤ 45 mA N/A ≤ 50 mA N/A ≤ 50 mA
Protection Circuit N/A Reverse power protection circuit, output short overcurrent protection circuit N/A Reverse power protection circuit, output short over current protection circuit, surge protection circuit N/A Reverse power protection circuit, output short over current protection circuit, surge protection circuit
Insulation Resistance N/A ≥ 20 MΩ (500 VDC, Megger)
Dielectric Strength N/A Between the charging part and the case: 1,000 VAC ~ 50/60 Hz for 1 minute
Display Part N/A N/A N/A Dual Display
Function N/A N/A N/A General Type
Vibration N/A N/A 1 mm double amplitude at frequency 10 to 55 Hz in each X, Y, Z direction for 2 hours N/A 1 mm double amplitude at frequency 10 to 55 Hz in each X, Y, Z direction for 2 hours
Shock N/A N/A 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times N/A 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Ambient Temperature N/A N/A -10 to 50 ºC, Storage: -20 to 70 ºC (No Freezing or Condensation) N/A -10 to 50 ºC, Storage: -20 to 70 ºC (No Freezing or Condensation)
Ambient Humidity N/A N/A 35 to 85% RH, Storage: 35 to 85% RH (No freezing or Condensation) N/A 35 to 85% RH, Storage: 35 to 85% RH (No freezing or Condensation)
Connection N/A N/A Connector Cable N/A Connector Cable
Features N/A
  • Auto sensitivity setting (button setting) / remote sensitivity setting type
  • External synchronization input, mutual interference protection, self-diagnosis
  • Reverse power protection and output short overcurrent protection circuit
  • Timer function: OFF delay timer approx. 40 ms fixed. (standard type, remote sensitivity setting type only)
  • Automatically selectable Light ON / Dark ON
  • Precise detection of small target and easy to install in the complicated place
N/A
  • Dual-display for light incident level and setting value (BF5-D)
  • Enables to detect the minute object with 1/10,000 high resolution
  • Enables to detect with high-speed moving object (response time 50 ㎲)
  • 5 response times: ultra fast mode (50 µs), fast mode (150 µs), standard mode (500 µs), long distance mode (4 ms), ultra long distance mode (10 ms)
  • Anti-saturation setting function prevents malfunction by saturated light
  • Easy sensitivity setting
  • Long lasting amplifier regardless of element’s life degradation or temperature change
  • Multiple sensitivity setting modes available: auto-tuning, 1-point (maximum sensitivity), 2-point, positioning teaching
  • Up to 8 units enable to connect with mutual interference prevention function using side connectors
  • Auto channel setting function for multiple installations
  • Adopts red, green, blue light sources
  • Slim design with depth 10 mm (W 10 × H 30 × L 70 mm)
N/A
  • Dual-display for light incident level and setting value
  • Enables to detect the minute object with 1/10,000 high resolution
  • Enables to detect with high-speed moving object (response time 50 ㎲)
  • 5 response times: ultra fast mode (50 µs), fast mode (150 µs), standard mode (500 µs), long distance mode (4 ms), ultra long distance mode (10 ms)
  • Anti-saturation setting function prevents malfunction by saturated light
  • External input: emitter OFF, remote sensitivity setting, peak reset, output ON/OFF/Keep, energy saving OFF
  • Multiple sensitivity setting modes available: auto tuning (fine-adjusting sensitivity) teaching sensitivity setting (button or external input auto-tuning, 1-point, 2-point, positioning)